CHY-113 layer thickness meter

It is usded to measure the thickness of metallic coatings (eg paint) only on substrates with ferromagnetic alloys (eg steel). The meter is designed to provide easy operation in one hand.

  • The scale thickness um / milsy (1/1000 inch)
  • Measuring range: 0 to 1000 microns (0 to 40.0 mils)
  • Accuracy: ± 4c: 0 to 7.8 mils ± 7c: 0 to 199 microns ± (3% 4 c) ÷ 200μm 1000μm (7.9 to 40 mils)
  • Max Resolution: 1 micrometer (0.1 mils)
  • Temperature Coefficient: ± 0.1% of reading / ° C (° F) in the temperature range
  • Above 28 ° C (82.4 ° F) and below 18 ° C (64.4 ° F)
  • Response time: 1 s